Professional Safety Services (UK) LtdProfessional Safety Services (UK) LtdProfessional Safety Services (UK) LtdProfessional Safety Services (UK) Ltd
    0
  •   was successfully added to your cart.
  • Home
  • Sales
    • Gas Detectors
      • Single Gas Detectors
      • Multi Gas Detectors
      • Area Gas Detectors
    • Breathing Apparatus
      • Escape Sets (EEBA)
      • Self Contained Breathing Apparatus (SCBA)
      • Positive Pressure Face Masks (PP)
      • Airline Breathing Apparatus
      • Cylinders
      • Fresh Air Breathing Apparatus
    • Access & Fall Arrest Equipment
      • Confined Space Kits
      • Harnesses
      • Work Positioning
      • Lanyards
      • Fall Arrest Blocks
      • Load Arrester Blocks
      • Confined Space Tripods
      • Fall Arrest-Retrieval Blocks
      • Man-Riding Winches
    • Davit Systems
      • Portable Davit System Kits
      • Lower Upper & Davit Masts
    • Rescue & Resuscitation
    • Personal Protective Equipment (PPE)
      • Respirators – Powered Air Respirators & Filters 
        • Respirators
        • Powered Air Respirators
        • 3M Bayonet Series Filters
        • 3M Secure Click Series Filters
        • 3M Scott DT-Series Filters (Pro2000)
      • Safety Helmets
      • Earplugs & Ear Defenders
      • Safety Glasses & Goggles
      • Face Shields & Visors
    • Underground Utility Location Equipment
      • Water Pipe Locator
      • Cable Avoidance Tools
      • Sondes and Flexitrace
    • ATEX Lighting Equipment
  • Hire
    • Gas Detector Hire
    • Breathing Apparatus Equipment Hire
    • Access & Fall Arrest Equipment Hire
    • Confined Space Kit Hire
    • Davit System Hire
    • Emergency Rescue Equipment Hire
    • Cable Avoidance & Survey Equipment Hire
  • Servicing
  • Fixed Gas
  • Contact Us

Fixed Gas Detection

    Home Fixed Gas Detection

    Professional Safety Services (UK) Ltd is a Crowcon authorised fixed gas distributor and approved service centre. We offer a flexible range of fixed gas detection services and products which are able to detect flammable, toxic and oxygen gases, report their presence and activate alarms or associated equipment. We use a variety of measurement, protection and communications technologies and our fixed detectors have been proven in many arduous environments, including oil and gas exploration, water treatment, chemical plants and steel mills.

    Key sectors we work in include: Water Utility Networks: Gas Utility Networks: Electricity Utility Networks: Defence: Rail Networks: Government: Civil Engineering: Breweries

    Our service engineers are fully qualified CompEx trained and have undergone authorised service center certification training in fixed gas detection with our manufacturing partners. Calibration gasses and maintenance parts used are manufacturer certified and traceable with all records uploaded onto our 24-hour online service portal, which is complimentary for all customers.

    SERVICES INCLUDE: 

    • Supply of Fixed Gas Detectors  
    • Site Surveys & Consultations
    • Commission Services
    • Post-Install Familiarisation & User Training 
    • Maintenance & Calibration Services
    Fixed Gas Detection Services at Professional Safety Services UK Ltd

    CROWCON CONTROL PANELS

    Crowcon GM ADDRESSABLE

    Crowcon GM ADDRESSABLE Controllers
    Rack 19 inch rack mount option also available
    Power Typical power use without detector heads is 20 to 50 Watts
    Electrical Output 4-20mA 2 wire current sink

    4-20mA 3 wire current source

    RS-485 Modbus RTU

    Relays 5 Amp 30 Volt

    RJ45 network connection

    Operating Temperature -20 to + 50 degrees C
    Humidity 0 to 90% non-condensing
    Repeatability and drift Digital channels – no controller variability

    Analog channels – <1% FSD change over a 1 year period

    Approvals May be used in a non-hazardous area as part of an intrinsically safe system.
    EMC compliance CE marked

    Large Enclosure

    Enclosure material Fibreglass
    Dimensions 612.4mm x 687.3mm x 241.6mm (24.11 x 27.06 x 9.51 inches)
    Weight 25 Kg (55lbs)
    Ingress Protection NEMA 4X

     

    Small Enclosure

    Enclosure material Fibreglass
    Dimensions 406.4mm x 334.3mm x 215.9mm (16.00 x 13.16 x 8.50 inches)
    Weight 7.7 Kg (17 lbs)
    Ingress Protection NEMA 4X

    Crowcon’s range of GM Addressable Controllers comes in three variations, all with identical functionality, but with different channel input capabilities:

    • GM16: 1-16 Channel inputs
    • GM64: 1-64 Channel inputs
    • GM128: 1-128 Channel inputs

    All available as 19” rack mounted, with enclosure options available for GM16 & GM64. All of the addressable gas detection controllers are modular, so the controller can be configured exactly to requirements. They only include what is needed for the application to reduce complexity and cost. With the ability to group channels into zoned areas, data can be viewed in a variety of ways to provide comprehensive insight into the safety of your site. From 3-minuite trends of one channel to an analysis of up to 16 channels at a time, with direct to web page live feed communication for remote viewing, you can feel confident you have full visibility and control of your environment at all times.

    Crowcon Vortex

    Crowcon Vortex Control Panel
    Vortex Vortex Rack/Panel
    Size 470 x 306 x 170mm (18.5 x 12 x 6.5 ins) Rack display: standard 19” 3U
    Panel display: 441 x 128mm (cut-out 366 x 84.5mm)
    Modules, PSU and batteries are supplied separately for fitting within a cabinet.
    Weight 12Kg (27lbs) Dependant on configuration
    Enclosure material Back-box: Aluminium
    Front cover: ABS
    Not applicable
    Ingress protection IP66 Cabinet dependent
    Channels Up to 12 (1 to 3 4-way input modules)
    Operating temperature -10°C to +40°C (14°F to +140°F)
    Humidity 0-95% RH non-condensing
    Inputs Gas    2 or 3 wire 4-20mA (sink or source), 0-5V
    Fire – smoke & heat detectors, manual call-points   Up to 3 loops, Up to 20 devices per loop
    Outputs External audible/visual alarm drive Via relays, four 24Vdc 0.5A supplies provided.
    Relays Type    Up to 24 SPCO, contacts rated 6A @ 250Vac (1 to 3 8-way relay modules) Up to 32 SPCO with bus extension module
    Assignment – Common Mains fail, battery low and fail
    Assignment – Voting Alarms, faults and system events
    Relay modes    Energised/de-energised, latched/non-latched, time-delayed, pulsed
    Digital communications DCS/PLC/PC:  RS-485 Modbus or Profibus
    Local configuration link: RS-232 (configuration software and lead supplied)
    Event logging Up to 300 alarm, power, fault, system events are stored in Non-Volatile Memory
    Panel indication Channel number:  2-digit 7-segment Green LED
    Gas reading: 4-digit 7-segment Red LED
    Measurement units:  % LEL, ppm, % Vol, Fire
    Power:  Green LED
    Battery OK:  Green LED
    Run/hold indication:  Green LED
    Channel test mode:  Flashing Amber LED
    System fault – integrity watchdog:  Amber LED
    Alarm indication Audible – internal sounder:  Piezo
    Visual – Alarm: Level 1 & 2, Red LED; Fault – Per channel, Amber LED; Inhibit – Per zone, Amber LED
    Power AC mains: 110/120V & 220/240Vac (switchable) 50-60hz 3.2A max
    DC: 20-30Vdc
    Battery back-ip: 2Ah internal
    Approvals Low voltage directive: EN61010-1
    EMC: Directive 2014/30/EU: EN50270, FCC: CRF47 Part 15, ICES-003
    ATEX: Ex II 2G D Zone 1, Zone 2, IECEx optional

    Even for large, complex sites with a variety of detection needs, the Vortex provides streamlined management of up to 12 devices, including 3 for fire, making it easy for you to have full visibility and control of your site. Each channel has 1 fault level and 3 alarm levels, which can be combined in any pattern to trigger up to 32 output relays. Designed with flexibility in mind, while the Vortex will initially be configured to suit your operational needs, channels and alarms can be easily customised by you, if requirements change, making the Vortex an adaptable solution. Vortex Rack & Panel formats comprise just the essential input, output and controller modules mounted on a DIN rail, with an optional display module available in panel-mounting and 19″ Rack formats. This configuration is ideal for incorporation into a variety of specialist enclosures, such as 19″ format or those with high ingress protection. A flameproof version is also available. Other standard features include RS-485 Modbus communications for remote non-intrusive calibration and configuration.

    Crowcon Gasmaster

    Crowcon Gasmaster Control Panel

    Gasmaster is a compact, versatile and powerful gas detection control panel that combines simple operation with an extensive array of input and output functions. Gasmaster provides all the information you need about your gas and fire detectors at a glance. The large multi-lingual display shows gas levels from all detectors simultaneously, with a user-friendly menu system that is intuitive, making system adjustment and testing using buttons on the front panel a straight forward process requiring minimal training.

    Size 288 x 278 x 110mm (11.3 x 10.9 x 4.3 inches)
    Weight 4.5kg (10lbs)
    Enclosure material Back-box: cast aluminium
    Front cover: ABS (flame retardant)
    Ingress protection IP65
    Power 100-240Vac 50-60Hz or
    20-30Vdc, 60W max
    Battery back-up 1.2Ah batteries fitted internally
    Operating temperature -10°C to +50°C (14°F to +122°F)
    Inputs Gas    One 2 or 3 wire 4-20mA gas detector (sink or source) or mV pellistor flammable gas detector One to four 2 or 3 wire 4-20mA gas detectors (sink or source) or mV pellistor flammable gas detectors
    Fire     One loop of up to 20 conventional smoke/heat detectors or manual call points, or one flame detector (4-20mA or digital contact signal) One to four loops of up to 20 conventional smoke/heat detectors or manual call points, or one to four flame detectors
    ESU    For use with one Crowcon ESU fan
    Remote inhibit/retest    Via normally open contact
    Outputs Relays DPCO contacts rated 250Vac 8A
    Low alarm. High alarm. Fault. Alarm relays can be set for rising or falling alarms. Hysteresis can be adjusted on low alarms
    Low alarm and high alarm per channel plus common low, high and fault. Alarm relays can be set for rising or falling alarms. Hysteresis can be adjusted on low alarms
    A/V alarm drive    12Vdc or 24Vdc 650mA max. drive. Suitable for +ve or -ve switched alarms
    Analogue     4-20mA (current source, max. loop resistance 700?) or 1-5Vdc (min. load 50k? ) 4-20mA for each channel (current source, max. loop resistance 700?) or 1-5Vdc (min. load 50k?)
    Serial link    RS-485 Modbus RTU for monitoring and control via DCS/SCADA/PLC systems
    Communications port Optional port for PC configuration and event log upload
    Event logging* Time-stamped log of up to 300 alarms, fault or system intervention activities
    Panel indication LCD back-lit display shows gas level (in ppb, ppm, % volume or % LEL units), and scrolling alpha-numeric status indication.
    LED’s for Alarm, Fault, Power and Warning. Integral 85dB sounder (at 10cm)
    Approvals EMC: EN50270, EN60945, FCC: CFR 47 Part 15; ICES – 003

    *Event log access requires a Gasmaster PC communications kit and communications port (see Accessories).

    CROWCON FIXED GAS DETECTOR HEADS

    Crowcon Xgard

    Even for large, complex sites with a variety of detection needs, the Vortex provides streamlined management of up to 12 devices, including 3 for fire, making it easy for you to have full visibility and control of your site. Each channel has 1 fault level and 3 alarm levels, which can be combined in any pattern to trigger up to 32 output relays. Designed with flexibility in mind, while the Vortex will initially be configured to suit your operational needs, channels and alarms can be easily customised by you, if requirements change, making the Vortex an adaptable solution. Vortex Rack & Panel formats comprise just the essential input, output and controller modules mounted on a DIN rail, with an optional display module available in panel-mounting and 19″ Rack formats. This configuration is ideal for incorporation into a variety of specialist enclosures, such as 19″ format or those with high ingress protection. A flameproof version is also available. Other standard features include RS-485 Modbus communications for remote non-intrusive calibration and configuration.

    The Xgard range is a comprehensive selection of fixed multi gas detectors that meet the diverse requirements for gas detection globally. Whether you need gas detection around water treatment facilities, oil and gas, power, research facility or manufacturing installations, with three different sensors to choose from, there will be an Xgard to suit your needs.

    Xgard offers three different sensor concepts so you can choose exactly what you need for your site. Xgard is available in flameproof, intrinsically safe, or safe area formats for use in all environments, whatever the classification.

    The Xgard range offers a comprehensive selection of fixed point gas detectors that meet the diverse requirements for flammable and toxic gas detection and oxygen monitoring in industries throughout the world.

    Whichever version of the Xgard you choose, you can be confident that they’re all designed to operate in even the harshest conditions, and can be manufactured using materials which can withstand the conditions of your specific space.

    With flexible installation options, the Xgard series can be either wall or ceiling mounted, without the need for additional brackets. Designed for easy installation, the replacement of sensors and sinters is extremely simple all helping to keep maintenance costs down.

    Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Xsafe
    Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
    Weight Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) 1.5 kg (3.3lbs) Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) 1kg (2.2lbs)
    Enclosure material ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Aluminium or 316 Stainless Steel Aluminium Aluminium or 316 Stainless Steel Aluminium
    Ingress protection IP65 IP54 IP65
    Cable entries 1 x M20, or 1/2 “NPT on right-side
    Terminations 0.5 to 2.5mm2
    Sensor type Electrochemical Catalytic bead 316 S/S sensor housing with catalytic beads Catalytic bead Thermal conductivity Catalytic bead
    Operating temperature -20 to +50 °C
    (-4 to 122 °F)
    (sensor dependant)
    -20 to +50°C (-4 to 122°F) -40 to +80°C
    (-40 to 176°F)
    -20 to +150°C (-4 to 302°F) -40 to +55°C (-40 to 131°F) +10 to +55°C (50 to 301°F) mV: -40 to +80oC (-40 to 176oF)
    mA: -40 to +55oC (-40 to 131oF
    Humidity 10 to 95% RH non-condensing 0-99% RH non-condensing 0-90% RH 0-99% RH
    Repeatability Zero drift <2% FSD (Typical)<2% FSD per Month (Typical)
    Response time T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) T90 <15s (Typical)
    Operating voltage 11-30V dc 2.0V dc +/- 0.1V (Typical) 10-30V dc mA: 10- 30V dc mV:2.0Vdc
    Power requirements 24mA maximum 300mA (Typical) 50mA at 24V dc 1.2W MA:50mA at 24V dc 1.2W mV: 300mA (Typical)
    Electrical output 2- wire 4-20mA (current sink) 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 3- wire 4-20mA (current sink or source) mA: 3- wire 4-20mA (current sink or source) mV: 3- wire mV bridge
    Typical signal: 12-15mV/ %LEL CH4
    Approvals ATEX: II 1 G
    Exia IIC T4 Ga
    (Tamb -40 to +55°C)
    UL/cUL: Class I, Div. 1
    Groups A, B, C, D
    IECEx
    ATEX: II 2GD
    Exd IIC T6 Gb (Tamb -40 to +50°C)
    UL: Class I, Div. 1
    Groups B, C, D
    IECEx
    ATEX: II 2 GD
    Exd IIC T4 Gb
    (Tamb -40 to +80°C)
    Exd IIC T6 Gb (Tamb -40 to +50°C)
    Ex tb IIIC
    T180°C Db
    UL: Class I, Div. 1
    Groups B, C, D
    IECEx
    ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) ATEX/IECEx: II 2 GD

    Ex db IIC T4 Gb – Ex tb IIIC T110˚C Db

    (Tamb -40 to +80˚C)

    Ex db IIC T6 Gb – Ex tb IIIC T80˚C Db

    (Tamb -40 to +50˚C)

    UL : Class I, Div 1

    Groups B, C, D

    EMC compliance EN 50270       FCC Part 15    ICES- 003

    *3/4 ” cable entry only available on aluminium junction boxes.

    Crowcon Xgard-Bright

    Crowcon Xgard-Bright Fixed Gas Detector

    Available with MPS technology to eliminate risk of poisoning and need for calibration, the Xgard Bright is the next generation of multi-gas detection. This fixed detector offers flammable and toxic gas detection and oxygen monitoring, combined with reduced installation costs and ease of operation.

    Xgard Bright is a versatile detector offering flammable and toxic gas detection and oxygen monitoring, while providing ease of operation and reduced installation costs.

    Choose from durable sensor options to suit your needs, such as MPSTM (10+ years), Long-life O2 (5 years) and IR sensors (10+ years) to prevent frequent sensor replacements and minimise operational expenses.

    Lowering the cost of installation, the 4-wire addressable implementation drastically reduces cabling requirements. The large OLED display allows users to easily work with Xgard Bright during install, calibration and routine maintenance without the need to open the housing.

    Providing analogue 4-20mA and RS-485 Modbus signals as standard, Xgard Bright comes with an Alarm and Fault relay as standard as well as optional HART communications.

    Size Aluminium enclosure:

    ATEX/IECEx: 156 x 166 x 109 mm (6.1 x 6.5 x 4.3 inch)

    UL: 162 x 166 x 110 mm (6.4 x 6.5 x 4.3 inch)

    Stainless Steel Enclosure:

    ATEX/IECEx: 165 x 166 x 105 mm (6.1 x 6.5 x 4.1 inch)

    UL: 162 x 166 x 103 mm (6.4 x 6.5 x 4.1 inch)

    Cable Gland Entry 2x M20 or 2x ½” NPT (Stopping plug fitted to the left-side entry)
    Operating Voltage 12-30Vdc.
    Power 3W max
    Electrical Output 3-wire 4-20mA (Sink or Source)
    RS-485 Modbus RTU
    HART 7 (Optional)
    Weight Aluminium enclosure:

    ATEX/IECEx: 1kg (2.2 lbs)

    UL: 1.5 kg (3.31 lbs)

    Stainless Steel Enclosure:

    ATEX/IECEx: 3.1 kg (6.8 lbs)

    UL: 3.5 kg (7.72 lbs)

    Enclosure Material ADC 12 aluminium alloy or 316 stainless steel
    Relay Alarm 1, Alarm 2, Fault (SPDT Contacts. Rated 1A, 24Vdc)
    Sounder Out High Side Switch (24V nominal, 12V minimum, 700mA maximum load)
    Operating Temperature ATEX/IECEx: -40°C to +70°C (-40°F to 158°F)

    UL: -40°C to +60°C (-40°F to 140°F)

    Humidity 0 to 95% RH, non-condensing

    Contact Crowcon for sensor operating humidity range.

    Repeatability +/- 2% FSD
    Zero drift +/- 2% FSD per year maximum
    Ingress protection IP65/66, EN 60529
    Hazloc Standards & Approvals

    Zone 1 and Zone 2 or Zone 21 and Zone 22

    Aluminium:

    Ex II 2 G Ex db IIC T6 Gb Tamb: -40°C≤Ta≤70 °C

    Ex II 2 D Ex tb IIIC T80°C Db

    Ex db IIC T6 Gb Tamb: -40°C≤Ta≤70 °C

    Ex tb IIIC T80°C Db

    Stainless Steel:

    Ex II 2 G Ex db IIC T3 Gb Tamb: -40°C≤Ta≤70 °C

    Ex II 2 G Ex db IIC T4 Gb Tamb: -40°C≤Ta≤50°C

    Ex II 2 D Ex tb IIIC T80°C Db

    Ex db IIC T3 Gb Tamb: -40°C≤Ta≤70°C

    Ex db IIC T4 Gb Tamb: -40°C≤Ta≤50°C

    Ex tb IIIC T80°C Db

    UL: UL 1203

    -40°C≤Ta≤60 °C

    Class I, Division 1, Groups B, C, D T6

    Class II Division 1, Groups E, F, G T6

    ApprovalsUL, IECEx, ATEX, CE, INMETRO, ECAS, PESO, CNEx, UC, CCSA TA, MEDEMC ComplianceEN 50270, EN IEC 61326-1, EN 55011, CISPR 11, EN 61000-4ZonesCertified for use in Zone 1 and Zone 2 areasWarranty

    2 years on transmitter

    5 years on MPS flammable and O2 Long Life sensor

    2 years on IR flammable sensors

    Refer to GEN067 – Warranty Periods

    for other sensors

    Xgard Bright Gases Sensor type Gas range Temp
    range °C 
    Flammable gases (Tested for Methane, Butane, Ethane, Ethylene, Hydrogen, LPG, Pentane, Propane) MPS 0-100% LEL -40 to +75
    Butane (C4H10) Infrared 0-100% LEL -40 to +60
    Hydrogen (H2) Catalytic 0-100% LEL -40 to +70
    LPG Catalytic

    Infrared

    0-100% LEL -40 to +70

    -40 to +60

    Methane (CH4) Catalytic

    Infrared

    0-100% LEL

    0-100% LEL

    -40 to +70

    -40 to +60

    Pentane (C5H12) Catalytic

    Infrared

    0-100% LEL

    0-100% LEL

    -40 to +70

    -40 to +60

    Propane (C3H8) Catalytic

    Infrared***

    0-100% LEL

    0-100% LEL

    -40 to +70

    -40 to +60

    Carbon Monoxide (CO) Electrochemical 0-25, 50, 100, 200, 250, 300, 1000, 2000 ppm -30 to +50
    Hydrogen Sulphide (H2S) Electrochemical 25, 50, 100, 200 ppm -40 to +50
    Oxygen (O2) Long Life (Lead free) Electrochemical 0-25% vol -40 to +60
    Oxygen (O2) Electrochemical 0-25% vol -20 to +50
    Carbon Dioxide (CO2) Infrared 0-5% vol -40 to +60
    Xsafe-Bright Gases Sensor type Gas range Temp
    range °C 
    Flammable gases* MPS 0-100% LEL -40 to +75
    Ammonia (NH3) Electrochemical 0-50, 100 ppm -40 to +50
    Chlorine (CL2) Electrochemical 0-5, 10 ppm -20 to +50
    Hydrogen Cyanide (HCN) Electrochemical 0-25 ppm -40 to +40
    Hydrogen Peroxide (H2O2) Electrochemical 0-5 ppm -20 to +50
    Sulphur Dioxide (SO2) Electrochemical 0-10 ppm -20 to +50
    VOC* PID 0-1000 ppm -20 to +60
    Ozone (O3) Electrochemical 0-1 ppm -20 to +40
    Carbon Dioxide (CO2) Infrared 0-5% vol -40 to +60

    Crowcon XgardIQ

    Crowcon XgardIQ Fixed Gas Detector

    XgardIQ is an intelligent and versatile fixed detector and transmitter. Its remote sensor and universal transmitter means you have access to Crowcon’s full range of sensor technologies and improved detection. With its sensor range selection capabilities it means users can set the full-scale range of the sensor according to specific location requirements.

    Available fitted with a variety of sensors for fixed flammable, toxic, oxygen or H2S gas detection, this SIL2 certified detector is easy and safe to use, with OLED display for easy visibility of reading even in dark locations and a +Ve safety indicator to quickly confirm the detector is operating soundly at a glance.

    The XgardIQ is optionally available with Alarm and Fault relays and HART communications.

    Size H278 x W140 x D89mm (10.9 x 5.5 x 3.5 in)
    Weight 4.1Kg (9lbs)
    Enclosure material 316 stainless steel
    Ingress protection IP66
    Connection Three M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries
    Power 14-30 VDC. <4W
    Display Main display – OLED 128 x 64 pixels, yellow text on black background
    Indicators – Amber, Red and Green LED’s for detector status; Blue +ve Safety LED
    Electrical output 4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant
    RS-485 Modbus RTU
    HART 7 over 4-20mA signal and via local I.S. test points (optional)
    Relays (optional)
    Alarm 1, Alarm 2, Fault
    SPCO contacts rated 5A, 230Vac
    Relay configuration options
    Energised or de-energised
    Latching or non-latching
    Rising or falling
    Configurable On and Off delays on alarm relays.
    Event logging Records alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC.
    Operating temperature ATEX/IECEx: -40°C to +75°C (-40°F to 167°F)
    FM: -40°C to +70°C (-40°F to 158°F)
    Refer to sensor datasheet for sensor operating temperature
    Humidity 0 to 95% RH non-condensing†
    Repeatability +/- 2% FSD
    Zero drift +/- 2% FSD per year maximum
    Response time Sensor dependant: contact Crowcon for specific sensor data.
    Hazloc standard & Approvals Zone 1 and Zone 2 or Zone 21 and Zone 22

    ATEX: EN IEC 60079-0, EN 60079-1, EN 60079-11
    Ex II 2 G Ex db ia IIC T4 Gb

    IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-11
    Ex db ia IIC T4 Gb

    FM Approval:
    US: ANSI/UL 60079-0, ANSI/UL 60079-1, ANSI/UL 60079-11 Class 1, Zone 1, AEx db ia IIC T4 Gb
    Canada: CSA C22.2 No. 60079-0, CSA C22.2 No. 60079-1, cSa C22.2 No. 60079-11 Ex db ia IIC T4 Gb

    Approvals CFMUS (Methane (Cat), Propane (Cat) and H2 S HT), IECEx, ATEX, CE, INMETRO, ECAS-Ex, PESO, CNEx
    Performance ANSI/FM/UL and EN 60079-29-1, ANSI/FM/UL 62990-1, EN 50271, EN 50104, EN 45544, UL/ANSI/ISA 92.00.01, FM 6320, FM 6340
    Functional safety SIL2 Certified, IEC 61508, EN 50402
    EMC Compliance EN 50270, EN IEC 61326-1, EN 55011, CISPR 11, EN 61000-4

    † Note: sensor operating temperature and humidity limits vary widely.** FM Approval is available for methane and propane pellistor sensors (part number XIQ-FA, XIQ-FB, XIQ-FC and XIQ-FD) and high temperature H2S sensor (part number XIQ-FT) versions only. FM Approved transmitters are limited to +70°C, FM Approved sensors may be used up to + 75°C.

    Gas Sensor Type Gas Range Temperature Range 
    Ammonia (NH3) Electrochemical 0-50 ppm, 0-100 ppm, 0-1000 ppm -20 to +40°C
    Carbon Monoxide (CO) Electrochemical 0-250 ppm, 0-500 ppm, 0-1000 ppm  -30 to +50°C
    Chlorine (Cl2) Electrochemical 0-5 ppm, 0-10 ppm, 0-20 ppm -20°C to 50°C
    Hydrogen Fluoride (HF) Electrochemical 0-10 ppm +5 to +40°C
    Hydrogen Sulphide (H2S) Electrochemical 0-100ppm -30°C to 70°C
    Hydrogen Sulphide (H2S) Electrochemical 0-25 ppm, 0-50 ppm -40°C to 50°C
    Hydrogen Sulphide (H2S) Electrochemical 0-100 ppm, 0-200 ppm -30°C to 50°C
    Oxygen (O2) Electrochemical 0-25% Vol. -20°C to 50°C
    Ozone (O3) Electrochemical 0-1 ppm -20°C to 40°C
    Sulphur Dioxide (SO2) Electrochemical 0-10 ppm, 0-100 ppm -30 to +50°C
    Flammable Gases* MEMS 0-100% LEL -40°C to 75°C
    Acetylene (C2H2) Catalytic 0-100% LEL -20°C to 60°C
    Benzene (C6H6) Catalytic 0-100% LEL -20°C to 60°C
    Ethanol (C2H6O) Infra-Red 0-100% LEL 10°C to 50°C
    Heptane (C7H16) Catalytic 0-100% LEL -20°C to 60°C
    Hydrogen (H2) Catalytic 0-100% LEL -40°C to 75°C
    LPG Catalytic
    Infra-Red
    0-100% LEL -20°C to 70°C
    -20°C to 55°C
    Methane (CH4) Catalytic
    Infra-Red
    0-100% LEL -40°C to 75°C
    -20°C to 55°C
    Pentane (C5H12) Catalytic
    Infra-Red
    0-100% LEL -40°C to 75°C
    -20°C to 55°C
    Propane (C3H8) Catalytic
    Infra-Red
    0-100% LEL -40°C to 75°C
    -20°C to 55°C

    • About Us
    • Social Value
    • Terms and Conditions
    • Online Maintenance Portal
    • Privacy Policy
    • Cookie Policy
    • Modern Slavery Policy
    • Anti-Bribery & Corruption Policy

    Recent Posts

    Copyright 2026 | Professional Safety Services (UK) Limited | Company Number: 06341353 | Registered in England & Wales | VAT registered GB 916 5428 16
    • Home
    • Sales
      • Gas Detectors
        • Single Gas Detectors
        • Multi Gas Detectors
        • Area Gas Detectors
      • Breathing Apparatus
        • Escape Sets (EEBA)
        • Self Contained Breathing Apparatus (SCBA)
        • Positive Pressure Face Masks (PP)
        • Airline Breathing Apparatus
        • Cylinders
        • Fresh Air Breathing Apparatus
      • Access & Fall Arrest Equipment
        • Confined Space Kits
        • Harnesses
        • Work Positioning
        • Lanyards
        • Fall Arrest Blocks
        • Load Arrester Blocks
        • Confined Space Tripods
        • Fall Arrest-Retrieval Blocks
        • Man-Riding Winches
      • Davit Systems
        • Portable Davit System Kits
        • Lower Upper & Davit Masts
      • Rescue & Resuscitation
      • Personal Protective Equipment (PPE)
        • Respirators – Powered Air Respirators & Filters 
          • Respirators
          • Powered Air Respirators
          • 3M Bayonet Series Filters
          • 3M Secure Click Series Filters
          • 3M Scott DT-Series Filters (Pro2000)
        • Safety Helmets
        • Earplugs & Ear Defenders
        • Safety Glasses & Goggles
        • Face Shields & Visors
      • Underground Utility Location Equipment
        • Water Pipe Locator
        • Cable Avoidance Tools
        • Sondes and Flexitrace
      • ATEX Lighting Equipment
    • Hire
      • Gas Detector Hire
      • Breathing Apparatus Equipment Hire
      • Access & Fall Arrest Equipment Hire
      • Confined Space Kit Hire
      • Davit System Hire
      • Emergency Rescue Equipment Hire
      • Cable Avoidance & Survey Equipment Hire
    • Servicing
    • Fixed Gas
    • Contact Us
    Professional Safety Services (UK) Ltd